CHOOSING THE BEST GENERATOR FOR THE JOB
These are the things to consider when selecting a generator:
HOW DO YOU PLAN TO USE YOUR GENERATOR?
Generators are used to perform a wide variety of tasks, and Honda offers a variety
of models to suit almost all potential users. Honda generators provide a high quality
power source that is reliable and convenient.
-
Camping/Recreation/Boating
- Home Standby
- Construction/Rental
HOW QUIET DOES YOUR GENERATOR NEED TO BE?
Honda generators are known for quiet operation. Honda has engineered exceptionally
quiet portable models, but offers less costly options that may serve your application
at a lower cost. While a camping application may require a super quiet EU series
choice, home standby and construction applications would be satisfied with a deluxe
or industrial series model, and some applications will allow for the Economy series
that do not have the additional features required to provide quiet operation.
IS ELECTRIC START REQUIRED?
Honda engines are renown for the ease of starting, even when only equipped with
a manual recoil starter. Honda offers many models with the convenience of electric
start for applications that may require remote start or where the ease of electric
start is preferred.
DO YOU REQUIRE EASY TRANSPORT?
While all Honda Generators are Portable by definition, many models include standard
wheel kits for easy movement of the generator from storage to the work site. Consider
the options when selecting the right model for your application.
HOW MUCH POWER DO YOU NEED?
Generators produce AC voltage, very similar to the voltage available in your home,
however while your electric utility company produces sufficient power for all your
electric powered devices, a portable generator is limited in power output directly
relational to the engine horsepower. The amount of power that a generator can produce
is rated in watts. Rated power is generally 90% of maximum power as certain components
lose efficiency as they are heated from use. To determine wattage requirements you
should determine which devices need to be powered simultaneously and what the starting
requirement of the device is. A Wattage Calculator is provided to assist you. Remember
that with simple "Power Management" techniques, a small generator can provide adequate
power for home or recreational applications.
"MAXIMUM" AND "RATED" POWER
A generator should never be operated at its MAXIMUM power output for more than 30
minutes. RATED power, or the power that a generator can produce for long periods
of time, is a more reliable measure of generator power. Typically the RATED power
is 90% of the MAXIMUM power. For Example, a 2500 watt generator produces a MAXIMUM
2500 watts of power. This means at maximum power this generator could light up 25
100-watt light bulbs at the same time. The rated wattage of this generator would
be 2300 watts and should only be used to power 23 - 100 watt light bulbs. When considering
your power needs, first determine the highest power application such as a well pump
for home power or air compressor for the job site. The power required to start the
capacitor motor on these applications will determine the rated power of the generator
you should choose for your application.
TYPES OF LOADS
In the previous example, the light bulbs are the LOAD of the generator. A 2500 watt
generator can handle a LOAD of no more than 2500 watts maximum.
RESISTIVE LOADS:
The light bulb example is called a RESISTIVE type load and the POWER it requires
is pretty easy to understand. Other RESISTIVE types of LOAD are things like toasters,
convection ovens, hot plates, curling irons, coffee makers, stereos and TV's. RESISTIVE
LOADS are usually appliances that do not have electric motors.
RESISTIVE LOADS = 1 x Power
A REACTIVE load contains an electric motor. Some household appliances
like a furnace or refrigerator have internal fans that come on intermittently, so
extra wattage/power is needed to start the fan. Another example is power tools.
An appliance or tool with a reactive load may require up to three times as much
power (wattage) to START as it does to keep it running. Examples of REACTIVE
type loads:
- Refrigerators / freezers
- Furnace fans
- Well pumps
- Air conditioners
- Bench grinders
- Air compressors
- Power tools
REACTIVE LOADS = 3 x Power
RESISTIVE LOADS:
The equation shows the relationship between watts, volts and amps in a PURELY
RESISTIVE load. If you know any of the two variables, the third can
be calculated. Example: You want a generator to power a 1000 watt flood light. The
light is 120V and requires 1000 watts of power. Using the equation, we can calculate
that the floodlight will draw 8.3 amps of electrical current. For REACTIVE loads,
the equation shows only a general relationship between watts, volts and amps. That's
because the power requirements for REACTIVE loads changes with operating conditions.
Resistive Loads - Volts x Amps = Watts
REACTIVE LOADS:
When determining the proper generator for REACTIVE type loads, you must consider
three modes of operation:
STARTING - The electric motor requires more power to start. The
starting power required can be up to THREE times the running amount.
RUNNING - The power required to run the electric motor once it
has been started.
LOADED - When the electric motor begins to work (saw begins cutting
wood, drill begins drilling thru a wall), its power requirement will increase. This
is not applicable for most household appliances.
DATA TAG:
Method 2 requires a visual inspection of the data tag supplied by the electric motor
manufacturer. All electrical motors have a data tag attached to their bodies that
give volts, amps, phase, cycles, hp, and sometimes a code. Volts (V) - The volts
must be either 120 (110-120) or 120/240. 120/240 means that the motor can be wired
to operate on 120V or 240V. Honda generators are either 120V or 120/240V. Amps (A)
- Indicates the amps required to RUN the electric motor but doesn't consider STARTING
or LOADED power requirements. Phase (PH) - Honda Generators can power only single
phase motors only. Horsepower (HP) - Rating of how much work an electric motor can
perform. Code - This isn't always provided on the data tag. It represents the maximum
STARTING power required of the electric motor. Cycles (Hz) - All of U.S. electrical
appliances run at 60 cycles per second.
LOAD CODE:
Is a letter which represents Amps per Hp to start the motor. Multiply CODE (amps)
times Hp of motor to determine starting amps. For example: The data tag on our electric
motor shows a code of L. Our motor is 1/3 Hp. An L code is 84 amps per Hp x 1/3
(motor Hp) = 28 amps to start the motor shown.
|
CODE
|
AMPS PER HP TO START |
CODE
|
AMPS PER HP TO START |
|
A |
26.0 |
L |
83.3 |
|
B |
29.5 |
M |
93.3 |
|
C |
33.3 |
N
|
104.0 |
|
D |
37.4 |
P |
116.6 |
|
E |
41.6 |
R |
133.3 |
|
F |
46.6 |
S |
149.9 |
|
G |
52.4 |
T |
166.6 |
|
H |
59.0 |
U |
186.6 |
|
J |
66.6 |
V |
more than 186.6 |